 |
01. |
Poor Value Perception |
 |
02. |
Poor Safety Awareness |
 |
03. |
Inadequate Risk Recognition |
 |
04. |
Insufficient Analysis or Research |
 |
05. |
Insufficient Prior Research |
 |
06. |
Corrosion/Flow |
 |
07. |
Ignorance |
 |
08. |
Insufficient Knowledge |
 |
09. |
Insufficient Study |
 |
10. |
Oxidation Reaction |
 |
11. |
Planning and Design |
 |
12. |
Poor Planning |
 |
13. |
Poor Operation Planning |
 |
14. |
Non-Regular Action |
 |
15. |
Change |
 |
16. |
Flow Rate Change |
 |
17. |
Bad Event |
 |
18. |
Thermo-Fluid Event |
 |
19. |
Temperature Rising |
 |
20. |
Failure |
 |
21. |
Abrasion |
 |
22. |
Corrosion |
 |
23. |
Secondary Damage |
 |
24. |
External Damage |
 |
25. |
Fire |
 |
26. |
Loss to Organization |
 |
27. |
Economic Loss |
 |
28. |
Manetary Damage 160 million yen |
|
|
 |

Leakage and fire caused due to an abnormal reaction from contamination of a heat medium to raw materials in a heat exchanger type reactor having a corroded part at an acrolein manufacturing plant
|
 |
Knowledge Comment: |
 |
High temperature and corrosive, moreover absolutely inhibited contamination with opposite side material in the heat exchanger ! Careful judgment and sufficient study are required. Please more carefully ! |
|
|
|
|