01. |
Ignorance |
 |
02. |
Insufficient Knowledge |
 |
03. |
Insuficient Study and Experience |
 |
04. |
Poor Value Perception |
 |
05. |
Poor Safety Awareness |
 |
06. |
Wrong Risk Recognition |
 |
07. |
Insufficient Analysis or Research |
 |
08. |
Insufficient Prior Research |
 |
09. |
Insufficient Knowledge Characteristics |
 |
10. |
Planning and Design |
 |
11. |
Poor Planning |
 |
12. |
Poor Design |
 |
13. |
Non-Regular Action |
 |
14. |
Inaction |
 |
15. |
No Idea in Next Step |
 |
16. |
Bad Event |
 |
17. |
Chemical Phenomenon |
 |
18. |
Abnormal Reaction |
 |
19. |
Secondary Damage |
 |
20. |
External Damage |
 |
21. |
Explosion |
 |
22. |
Bodily Harm |
 |
23. |
Death |
 |
24. |
Loss to Organization |
 |
25. |
Economic Loss |
 |
26. |
Monetary Damage 37 million yen |
|
|
 |

Run-away reaction occurred during vacuum distillation of epichlorohydrin waste liquid including dimethylsulfoxide
|
 |
Knowledge Comment: |
 |
For the first treating of dangerous material, there were insufficient pre-study and inadequate knowledge of heat exchange resulted an accident. |
|
|
|
|